BH93-S Series
Applications
OEM equipment
Refrigeration Level controls
HVAC
Fluids and gas measurement
Water Management
Environmental Data
Temperature Ranges Compensated: 0°C to 70°C
Operating: – 20°C to 85°C
Storage: – 40°C to 125°C
Specifications
Performance@25°C (77°)
Accuracy: 1.0%BFSL (optional 0.5%,0.2% and 0.1%) Stability: <0.2%FS/year, typical
Over pressure protection: 2 × Rated Pressure
Burst Pressure: 2.5 × mini
Pressure Cycles: > 50 Million
Excitation:
9-29 Vdc for 4-20mA
10Vdc for mV/V output
Electrical Rating: IEC Ex ia ‖C T5 Loop resistance@24 Vdc: 500 Ohm Zero offset:<±1% of FS
Span tolerance:<±1% of F
Output :⃰
4-20 mA; 10 Vdc(10mV/V ratio metric); 1-5 Vdc;0.5- 4.5 Vdc
⃰ Consult with factory for other output options
Physical Data:
Sensor wetted material: 316L SS
Body material: 316L SS
Cable pull strength: 200 lb.
Pressure connection: Nose-cone over1/4” mnpt ⃰ (see Pressure connection below for other options) Electrical Connection : Molded, vented submersible cable(PE outer jacket)